<ErrorNumber>15331</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: STEP : axis 2 HOME limit switch is active
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
First try selecting the RESUME button on the workstation dialog box a few times.
If this does not make the problem go away, then make sure that the unload
traveller is not stuck in the HOME position. Try moving the traveller away from
the HOME position by hand and select the RESUME button again. If the
problem persists, then Creo Service should be called.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
This error occurs when the stepper motor HOME switch becomes active before the
stepper motor has finished moving.
</text></DescriptionText>
<DescriptionText><text>
The sensor status may be checked by using the TABLE command. The sensor status
should read TRUE if the sensor is activated.
</text></DescriptionText>
</ServiceInformation>
<Cause>
If the procedure described in Operator Action does not correct the problem, then
the stepper controller must be re-initialized. Do this either by typing TABLE
INIT or (if that does not work) resetting the recorder.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:02 2008 PST
</Updated>
<Links>
</Links>
</Error>